Generator Size Calculator

Pick the circuits you want to keep on during an outage and see the generator class that covers them, in kilowatts.

Tap to CallNumber arriving soon

A real person answers. Free estimate, no obligation.

Instant estimate No sign-up One tap to a pro

Generator Size Calculator

Massachusetts · typical January low 22°F
Portable generator, 3.5 to 7.5 kW
6 kW
Recommended generator size, with 20 percent headroom
3,350 W
Running watts
1,550 W
Largest starting surge

About 6 kW covers what you checked with headroom. Portable generator, 3.5 to 7.5 kW, connected through a transfer switch or interlock.

In Massachusetts, a winter outage puts the furnace blower and the sump pump first in line, since a cold house and a wet basement are the two outage problems that get worse by the hour.

What was counted (running / starting watts)

  • Refrigerator: 700 / 2,200 W
  • Sump pump: 1,050 / 2,150 W
  • Furnace blower: 800 / 2,350 W
  • Lights: 500 / 500 W
  • TV, modem and router: 300 / 300 W

Connection and fuel

  • A portable generator connects to the house through a manual transfer switch or a breaker interlock that an electrician installs at the panel. Never feed a generator into a wall or dryer outlet: it sends power out to the utility lines and can injure a line worker.
  • Gasoline portables typically run 8 to 12 hours on a tank at half load. Store fuel with stabilizer, and run the unit outdoors at least 20 feet from windows and doors because of carbon monoxide.
  • Dual-fuel portables also run on propane, which stores for years without going stale.

A sizing estimate from typical wattages, not your nameplates. An electrician sizes the transfer switch, checks the fuel supply, and pulls the permit.

A sizing estimate from typical wattages, not your nameplates. An electrician sizes the transfer switch, checks the fuel supply, and pulls the permit.

Data: typical running and starting wattages from U.S. DOE Energy Saver appliance guidance and manufacturer generator sizing charts; motor starting surge from National Electrical Code locked-rotor conventions described in words, 2026 · Updated September 2026

How generator sizing works

Running watts add up

Each appliance you check has a typical running wattage, the power it draws once it is going. Those are summed for the base load.

One motor starts at a time

Motors like a refrigerator compressor, sump pump, well pump, or air conditioner pull two to six times their running watts for a moment at start. The calculator adds only the largest single surge on top of the running total, the standard sizing approach, since motors rarely all start in the same second.

Headroom and the class

Twenty percent headroom is added so the unit is not running flat out, then the result lands in a class: portable, large portable, air-cooled standby, or whole-home. Big 240-volt loads like central air and a well pump are what push a house into standby territory.

The connection is the real job

Any generator that powers house circuits connects through a transfer switch or interlock at the panel. An electrician installs it, and standby units add gas or propane supply and an automatic switch. The sizing here gets you ready for that conversation.

Common questions

What size generator runs a whole house?

A typical house with central air, a well pump, and electric cooking or drying lands in the 20 to 26 kW range without load management. With an automatic load-shedding module that runs the big loads one at a time, a 14 to 22 kW standby unit often covers the same house.

Can a portable generator run my central air conditioner?

A 2-ton unit can sometimes start on a large portable with a 240-volt outlet. Three tons and up usually needs 10 kW or more unless the air conditioner has a soft-start kit, which cuts the starting surge roughly in half.

Portable or standby?

Portable units cover the basics for a few hours at a time and need you home to start them and refuel. Standby units start on their own within seconds, run on natural gas or propane, and carry the whole house or a chosen set of circuits. Long or frequent outages, a sump pump, a well, or medical equipment tip the choice toward standby.

Why can I not just plug the generator into a wall outlet?

Feeding power backward through an outlet, called backfeeding, sends electricity out to the utility lines and can injure a line worker, and it bypasses every protection in the panel. A transfer switch or interlock, installed by an electrician, is the accepted connection.

How long will the fuel last?

A gasoline portable typically runs 8 to 12 hours on a tank at half load. Propane stores for years without going stale. Natural gas standby units run as long as the utility gas flows, which is the reason most permanent installs use it.

Get an exact answer from a local pro

Free to call — get connected with a local pro in your area.

Tap to CallNumber arriving soon

Keep going

Find a local pro in MassachusettsAll tools & calculators

disclaimer: 781 Heating is a free service to assist homeowners in connecting with local service providers. All contractors/providers are independent and 781 Heating does not warrant or guarantee any work performed. It is the responsibility of the homeowner to verify that the hired contractor furnishes the necessary license and insurance required for the work being performed. All persons depicted in a photo or video are actors or models and not contractors listed on 781 Heating.

Same-day and 24/7 emergency services are subject to provider participation, location, technician availability, and demand. Availability is not guaranteed and may vary by market and appointment capacity.

We use cookies and session-based analytics, including session replays (with form inputs masked), to improve this site. See our Privacy Policy.

About · Contact · Privacy · Terms · Disclosure · Sitemap

© 2026 781 Heating. All rights reserved.